Two-site evaluation of the Roche Elecsys Vitamin D total III assay

Julien Favresse, Johan Schiettecatte, Fleur Wolff, Frederic Cotton, Marc Elsen, Christine Eucher, Catherine Rosseels, Ellen Anckaert

    Research output: Contribution to journalArticlepeer-review

    Abstract

    Objectives: The high request for vitamin D testing in the last decades has led manufacturers to develop assays on automated immunoassay platforms. The objective of this study was to evaluate the performance of the new Elecsys Vitamin D total III assay for the measurement of total 25(OH)D. Methods: A total of 844 serum samples collected in two clinical laboratories were used to evaluate the new Roche Elecsys Vitamin D total III assay. Comparisons with Roche Elecsys Vitamin D total II and liquid chromatography tandem mass spectrometry (LC-MS/MS) were carried out. Additionally, assay imprecision, linearity, matrix effects, biotin interference, cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3, and outlier rate were evaluated for the Elecsys Vitamin D total III assay. Results: Only the comparison between LC-MS/MS and Roche Elecsys Vitamin D total III achieved the optimal specification for bias (i.e., <3.4%). Imprecision, linearity and matrix effects showed acceptable results. The biotin interference threshold was increased up to 1,200 ng/mL and the outlier rate was low (0.26%). The cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3 was weak or modest in available patient samples. However, using SRM972a with a high level of 3-epi-25(OH)D3 (enriched) revealed an important cross-reactivity with both Roche Elecsys Vitamin D total II and III assays (+74.7% and +73.7%). Conclusions: In conclusion, the Roche Elecsys Vitamin D total III assay presents several advantages compared to the previous assay generation: higher biotin interference threshold, broader measuring range, and better comparability with LC-MS/MS. However, the cross-reactivity toward 3-epi-25(OH)D3 is still problematic in high titer samples.

    Original languageEnglish
    Pages (from-to)1598-1606
    Number of pages9
    JournalClinical Chemistry and Laboratory Medicine
    Volume60
    Issue number10
    DOIs
    Publication statusPublished - 1 Sept 2022

    Keywords

    • 25(OH)D
    • immunoassay
    • liquid chromatography tandem mass spectrometry (LC-MS/MS)
    • vitamin D

    Fingerprint

    Dive into the research topics of 'Two-site evaluation of the Roche Elecsys Vitamin D total III assay'. Together they form a unique fingerprint.

    Cite this