The underestimated issue of non-reproducible cardiac troponin I and T results: Case series and systematic review of the literature

Julien Favresse, Jean Louis Bayart, Damien Gruson, Sergio Bernardini, Aldo Clerico, Marco Perrone

    Research output: Contribution to journalReview articlepeer-review

    17 Downloads (Pure)

    Abstract

    Cardiac troponins (cTn) are the preferred biomarkers for the evaluation of myocardial injury and play a key role in the diagnosis of acute myocardial infarction (MI). Pre-analytical or analytical issues and interferences affecting troponin T and I assays are therefore of major concern given the risk of misdiagnosis. False positive troponin results have been related to various interferences including anti-troponin antibodies, heterophilic antibodies, or elevated alkaline phosphatase level. On the other hand, false negative results have been reported in the case of a large biotin intake. These interferences are characterized with erroneous but reproducible troponin results. Of interest, non-reproducible results have also been reported in the literature. In other words, if the sample is reanalyzed a second time, a significant difference in troponin results will be observed. These interferences have been named “fliers” or “outliers”. Compared to the biotin interference that received major attention in the literature, troponin outliers are also able to induce harmful clinical consequences for the patient. Moreover, the prevalence of outliers in recent studies was found to be higher (0.28–0.57%) compared to the biotin interference. The aim of this systematic review is to warn clinicians about these non-reproducible results that may alter their clinical judgment. Four case reports that occurred in the Clinique of Saint-Luc Bouge are presented to attest this point. Moreover, we aimed at identifying the nature of these non-reproducible troponin results, determining their occurrence, and describing the best way for their identification.

    Original languageEnglish
    Pages (from-to)1201-1211
    Number of pages11
    JournalClinical Chemistry and Laboratory Medicine
    Volume59
    Issue number7
    DOIs
    Publication statusPublished - 1 Jun 2021

    Keywords

    • Flyer
    • Outlier
    • Patient safety
    • Prevalence
    • Troponin

    Fingerprint

    Dive into the research topics of 'The underestimated issue of non-reproducible cardiac troponin I and T results: Case series and systematic review of the literature'. Together they form a unique fingerprint.

    Cite this