Comparison of the linking arm effect on the biological performance of a CD31 agonist directly grafted on L605 CoCr alloy by a plasma-based multistep strategy

Sergio Diaz-Rodriguez, Caroline Loy, Pascale Chevallier, Céline Noël, Giuseppina Caligiuri, Laurent Houssiau, Diego Mantovani

    Résultats de recherche: Contribution à un journal/une revueArticleRevue par des pairs

    Résumé

    Stents are cardiovascular implants deployed on atherosclerotic arteries that aid in reopening, sustaining, and avoiding their collapse. Nevertheless, postimplantation complications exist, and the risk of the renewal of the plaque subsists. Therefore, enhanced properties are mandatory requirements for clinics. For that purpose, a novel approach allowing the direct-grafting of bioactive molecules on cobalt-chromium devices (L605) has been developed. This original strategy involves the direct plasma functionalization of metallic surfaces with primary amines (-NH2). These groups act as anchor points to covalently graft biomolecules of interest, herein a peptide derived from CD31 (P23) with proendothelialization and antithrombotic properties. However, the biological activity of the grafted peptide could be impacted by its conformation. For this study, glutaric anhydride (GA), a short chain spacer, and polyethylene glycol (PEG) with antifouling properties were used as linking arms (LAs). The covalent grafting of the CD31 agonist on L605 by different LAs (GA-P23 and PEG-P23) was confirmed by XPS and ToF-SIMS analyses. The biological performance of these functionalized surfaces showed that, compared to the electropolished (EP) alloy, grafting the P23 with both LA increases adhesion and proliferation of endothelial cells (ECs) since day 1: EP = 68 ± 10%, GA-P23 = 101 ± 7%, and PEG-P23 = 106 ± 5% of cell viability. Moreover, ECs formed a complete monolayer at the surface, preventing clot formation (hemoglobin-free >80%). The potential of this plasma-based strategy for cardiovascular applications was confirmed by promoting a fast re-endothelialization, by improving the hemocompatibility of the alloy when coupled with the CD31 agonist and by its transfer onto commercial L605 stents, as confirmed by ToF-SIMS.

    langue originaleAnglais
    Numéro d'article051009
    Pages (de - à)051009
    journalBiointerphases
    Volume14
    Numéro de publication5
    Les DOIs
    Etat de la publicationPublié - 1 sept. 2019

    Empreinte digitale

    Examiner les sujets de recherche de « Comparison of the linking arm effect on the biological performance of a CD31 agonist directly grafted on L605 CoCr alloy by a plasma-based multistep strategy ». Ensemble, ils forment une empreinte digitale unique.

    Contient cette citation