Algorithm for Rapid Exclusion of Clinically Relevant Plasma Levels of Direct Oral Anticoagulants in Patients Using the DOAC Dipstick: An expert consensus paper

Job Harenberg, Robert Charles Gosselin, Adam Cuker, Cecilia Becattini, Ingrid Pabinger, Sven Poli, Jeffrey Ian Weitz, Walter Ageno, Rupert Bauersachs, Ivana Ćelap, Philip Choi, James Douketis, Jonathan Douxfils, Ismail Elalamy, Jawed Fareed, Anna Falanga, Emmanuel Favalor, Grigoris T Gerotziafas, Harald Herkner, Svetlana HetjensRobert Klamroth, Lars Heubner, Florian Langer, Gregory Yh Lip, Brain Mac Grory, Sandra Margetić, Anne Merrelaar, Marika Pikta, Thomas Renne', Michael Schwameis, Sam Schulman, Daniel Strbian, Alfonso Tafur, Francesco Violi, Julie Vassart, Jeanine Walenga, Christel Weiss

Résultats de recherche: Contribution à un journal/une revueArticleRevue par des pairs

54 Téléchargements (Pure)

Résumé

With the widespread use of direct oral anticoagulants (DOACs), there is an urgent need for a rapid assay to exclude clinically relevant plasma levels. Accurate and rapid determination of DOAC levels would guide medical decision-making to (a) determine the potential contribution of the DOAC to spontaneous or trauma-induced hemorrhage; (b) identify appropriate candidates for reversal, or (c) optimize the timing of urgent surgery or intervention. The DOAC Dipstick test uses a disposable strip to identify factor Xa- or thrombin inhibitors in a urine sample. Based on the results of a systematic literature search followed by an analysis of a simple pooling of five retrieved clinical studies, the test strip has a high sensitivity and an acceptably high negative predictive value when compared with levels measured with liquid chromatography tandem mass spectrometry or calibrated chromogenic assays to reliably exclude plasma DOAC concentrations >30ng/mL. Based on these data, a simple algorithm is proposed to enhance medical decision-making in acute care indications useful primarily in hospitals not having readily available quantitative tests and 24/7. This algorithm not only determines DOAC exposure but also differentiates between factor Xa- and thrombin inhibitors to better guide clinical management.

langue originaleAnglais
journalThrombosis and Haemostasis
Date de mise en ligne précoce5 févr. 2024
Les DOIs
Etat de la publicationE-pub ahead of print - 5 févr. 2024

Empreinte digitale

Examiner les sujets de recherche de « Algorithm for Rapid Exclusion of Clinically Relevant Plasma Levels of Direct Oral Anticoagulants in Patients Using the DOAC Dipstick: An expert consensus paper ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation